New Scenar Models PDF Print E-mail
ImageBreakthrough Russian Bio-Resonance Technology Reaches a New Level!



"Star Trek Made Reality."

Scenar Technology and the latest research instruments from Russia...
January 25, 2008

Skenar Products

The Skenar 97.4 + has just been replaced by a new model!
The RITMSCENAR Professional has full versatility in parameter adjustment - used as both a diagnostic research and experimental treatment device. There is a huge amount of research material on this instrument!

CE approved for pain relief in the United Kingdom!
Brand new model year 2004 which replaces the RITM profscenar 97.4+.

What is new?
Design, backlight, very low energy option, line screening, circle screening, service menu and DIAN (Off, 1, 2, 3, 4) leather wallet.

What is improved?
Bigger display, battery compartment (3 AA batteries), keypath, inner circuits connections, for left and right hand use.

The basic mode of operation of Scenar devices is to deliver a "dosage" of electrical stimulation impulses to the body via an in-built and/or remote electrode in direct contact with the skin surface. These impulses have been tailored to mimic the electrical discharges of the nervous system, in order to elicit the organism's response with optimum efficiency and minimum disruption to cell function, depending upon the unique requirements of the presenting pain disease dynamics (or lack of the same). The action is aimed at both the "fast" pain blocking A-fibres and the "slow" pain producing and peptide generating C-fibres.

In other words, the Scenar measures the electrical properties (impedence) of the skin to correct energetic imbalances. The Scenar measures response and mimics the signals sent by the brain to instruct the release of healing bio-chemicals such as neuropeptides. The basic idea is that the body becomes overwhelmed with so much "patterns of injury" that corrective electrical signals may not reach the most important injuries. A trained scenar researcher may be able to correct these electrical patterns allowing the body to heal itself much more easily.




The signal stream, comprising waveform, signal strength (voltage and current) and frequency, can be varied in a number of ways, either by preselection by the operator or automatically by the control circuitry of the device. The "dosage" can be delivered automatically or overridden at the discretion of the operator, with guidance from visual indicators on numeri LED display.

The basic signal component is a bipolar pulse, consisting of a negative square-wave followed by a positive saw-tooth, starting and finishing at zero and lasting for a few microseconds. A number of these pulses may be packaged into a discrete burst (intensity) which itself may be repeated at a fixed default frequency. The individual pulses in these bursts (intensity more than 1) can themselves be spaced out (Z=10/close together, to 80/wide apart) to give a concentrated (deep) or diffuse (shallow) penetration, depending on local body density or depth of pain location.

Alternatively, a single pulse (intensity=1) may be preselected to a pulse repeat rate (PRP) over a set frequency range (say F=15-351 Hz). The signal may also be "modulated":
AM=Off, 1:1, 1:2, 1:3, 1:4, 1:5, BEE (amplitude modulation),
FM=Off, On, Swing (frequency modulation),
DMPF=Off, Sk1, Sk2, Sk3, Sk4, Var.

These "modulations" can either be applied individually or together.

The purpose of all these variants is to make available to the operator a comprehensive arsenal with which to stimulate both acute and chronic conditions and prevent the body from adapting to the signal before there has been time to generate sufficient neuropeptides (endophins, etc.) to releave pain and create an enhanced environment for the organism to bring into play its own healing pharmacy to move towards homeostasis.

The power output can be set by the operator to be detectable but comfortable for the patient. It can also be adjusted during application should this be required. The maximum current output is 70 mA and the peak voltage is 180 V, derived from three internal AA batteries.

A further level of chaos is introduced by a random variation of the pulse amplitude from zero to the chosen comfort such that no two pulses are the same. This discourages adaptation in the organism. A feedback mechanism is provided by the constant monitoring of skin impedance, which will change with time and "dosage" delivered. Integration of these values permits calculation and display of rate of change (of current flow) and coefficient of waveform in relation to the starting point.

Scenar devices adhere to the concept that the maximum dosage required to effect change is the most appropriate. Ths is furthered by emphasis on increase of information rather than energy content, thus minimising the triggering of body retaliation and adaptation mechanisms.

Optional attachments: face, scalp and point.



Item #: EMF-EE-RITMPRO | Price: $2850.00 $2497.00

>> Click Here <<
And Get Your Scenar On It's Way
>> Right Now <<


The Autoscenar

New Home Use Model! The Autoscenar is an easy to use simplified version of the Skenar 97.4 with a host of automatic features. This model is designed for the home researcher wishing to explore this great Russian research technology which was studied on a secret base in the Soviet Union for 20 years.

NOTE: Both the Skenar and Autoscenar are sold for research purposes only and no medical claims can be made for them.